Your radiator is hot at the bottom and cold at the top. The room never quite warms up, so you keep nudging the thermostat. That's almost always trapped air, and you can clear it yourself in about 30 to 45 minutes with a radiator key that costs a few coins.
The short answer: switch the heating off and let it cool. Hold a cloth under the bleed valve and open it a quarter turn anticlockwise with a key or screwdriver. Close it when the hissing stops and water comes out in a steady stream. Do the radiators in order, downstairs and furthest from the boiler first. Then check the boiler pressure and top it up, usually to about 1 to 1.5 bar on a sealed system.
Here's the full sequence, the numbers behind it, and the point where you should stop and call someone.
1. Confirm it's air, not sludge
Run the heating for 15 to 20 minutes. Then carefully feel each radiator from top to bottom.
- Cold top, hot bottom: trapped air. Bleeding fixes this.
- Cold bottom, warm top: sludge (iron oxide) settled in the radiator. Bleeding won't help.
- Cold all over: a closed or stuck valve, or a system that needs balancing.
- Gurgling or knocking: usually air moving through the pipes.
What a cold top actually costs
Air doesn't burn fuel. It blocks heat. A radiator with its top quarter full of air gives out roughly a quarter less heat, though the exact loss varies with the radiator and water temperature.
Worked example: a radiator rated at 1,200 W loses about 300 W of output. Over a four-hour evening that's 1.2 kWh of heat that never reaches the room.
The real cost comes when you turn the thermostat up to compensate. A widely used rule of thumb is that each extra 1°C adds roughly 5 to 10% to heating energy use, depending on the home. Take a house using 40 kWh of gas a day in winter. That's 2 to 4 kWh extra per day. At an example tariff of 0.10 per kWh, it's 0.20 to 0.40 a day, or about 30 to 60 over a 150-day heating season.
Be honest about the payback. If you never touched the thermostat, bleeding saves you close to nothing. It restores comfort and stops the thermostat creep. Redo the sum with your own daily use and unit price.
2. Gather your tools
- A radiator key that fits the square spindle on the bleed valve.
- A flat-head screwdriver, if your valves have a slot instead of a square.
- An old towel for the floor and a cloth to catch drips.
- A small container or tray, about the size of a mug.
- Gloves. The water can be black and stains carpet.
No key? Look at the valve first. Many modern valves have a slot and take a screwdriver. For square spindles, a multi-tool with a radiator key insert works. Avoid pliers: they round the spindle, and then you'll need a plumber.
3. Switch the heating off and let it cool
Turn the heating off at the thermostat or controller. Wait 30 to 60 minutes.
Two reasons. First, system water often runs at 60 to 70°C or more, which can scald. Second, a running pump can pull air in through the open valve or push water out faster than you can catch it. On a combi boiler, also avoid running hot taps while you bleed.
4. Work in the right order
Air rises and collects at the highest points. So bleed in this order:
- Ground floor first, starting with the radiator furthest from the boiler.
- Work back towards the boiler.
- Then go upstairs and repeat: furthest first, nearest last.
- Single-storey home: simply go furthest to nearest.
Bleed every radiator, not just the cold one. Air shifts around once you start.
5. Bleed each radiator
The bleed valve sits at one top corner of the radiator. Follow this sequence at each one:
- Lay the towel on the floor below the valve. Hold the cloth and container just under it.
- Fit the key onto the spindle, or the screwdriver into the slot.
- Turn anticlockwise a quarter turn. Half a turn at most.
- Listen for hissing. That's air escaping. It usually takes 10 to 60 seconds.
- Wait for water to spit, then run as a steady, bubble-free stream.
- Turn clockwise to close. Snug, not forced.
- Wipe the valve dry and watch it for a minute to check for drips.
- Move to the next radiator in the order above.
If nothing comes out at all, close the valve. Either the system pressure is too low, or the valve is blocked. Check the pressure in step 6 before trying again.
6. Check and top up the boiler pressure
Every radiator you bleed releases a little water. On a sealed system, that drops the pressure.
- Find the gauge on the front or underside of the boiler.
- Read it cold. Most sealed systems sit around 1 to 1.5 bar when cold. Your boiler manual gives the exact figure.
- Below about 1 bar: top up using the filling loop, a braided hose or built-in tap with one or two valves.
- Open the valves slowly. Watch the needle rise. It usually takes 10 to 30 seconds.
- Close fully at your target pressure.
- Never go near 3 bar. That's where the safety relief valve typically opens and dumps water outside.
Some boilers use a key or lever instead of a hose. Follow the manual. Don't open the boiler casing.
Open-vented systems have a small header tank in the loft and usually no pressure gauge. They refill themselves, so skip the top-up.
7. Turn the heating back on and recheck
Switch the heating on. Run it for 20 to 30 minutes. Feel each radiator again, top to bottom.
Still a cold band at the top? Turn the heating off, let it cool, and bleed that radiator once more. Then check the pressure while the system is hot. A rise of roughly 0.5 bar from cold is normal. A reading falling over the following days is not.
Once a year, before the heating season, is a sensible routine. The US Department of Energy's Energy Saver guidance lists bleeding trapped air from hot-water radiators among basic heating maintenance.
Common mistakes
- Bleeding with the heating on. You risk scalding, and the pump can draw air back in. Always switch off and wait at least 30 minutes.
- Opening the valve too far. Turn it more than a full turn and the pin can come out completely. Water then pours out under pressure. Stick to a quarter to half turn.
- Forgetting the pressure afterwards. After bleeding several radiators, pressure can fall below 1 bar. Many boilers then lock out and stop heating. Check the gauge every time.
When to call a heating engineer
Bleeding is a safe DIY job. These signs mean it isn't the whole story:
- You need to bleed every few weeks. Constant air points to a leak, a faulty valve or corrosion producing gas inside the system.
- Pressure keeps dropping after you've topped up, with no visible leak.
- Radiators are cold at the bottom or the bleed water is black or thick. That's sludge, and it may need flushing.
- The valve is seized, snapped or leaking after you close it.
- Pressure climbs towards 3 bar or the relief pipe outside drips.
- The boiler shows a fault code that resetting doesn't clear.
For anything inside the boiler, use a qualified, registered heating engineer. Gas and combustion work isn't a DIY job.
Figures are worked examples: check your own tariff, the appliance labels and your local rules before you decide.